Product Code ME-2000-WPRU
EAN Code ME-2000-WPRU
Features
True double-conversion online UPS
Wide input voltage range (110-300 VAC)
Input power factor correction 0.99
Output power factor 0.8
Converter mode available
ECO mode operation for energy saving (only available for 1-3KVA)
Hot-swappable battery design only available for 1-3KVA
Generator compatible
Adjustable charging current via LCD or software (1A ~ 6A)
Specifications
Colour
Black
PHASE
Single phase with ground
CAPACITY
2000 VA / 1600 W
INPUT
Voltage Range
Low Line Transfer
160 VAC/140 VAC/120 VAC/110 VAC ± 5% (Ambient Temp. (based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)
Low Line Comeback
175 VAC /155 VAC/ 135 VAC /125 VAC± 5 % (Ambient Temp. (based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)
High Line Transfer
300 VAC ± 5 %
High Line Comeback
290 VAC ± 5 %
Frequency Range
40Hz ~ 70 Hz
Power Factor
? 0.99 @ nominal voltage
OUTPUT
Output Voltage
200/208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode)
± 1%
Frequency Range (Synchronized Range)
47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode)
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
Current Crest Ratio
3:1
Harmonic Distortion
? 3 % THD (Linear Load),
? 6% THD (non-linear load)
Transfer Time
AC Mode to Batt. Mode
Zero
Inverter to Bypass
4 ms (Typical)
Waveform (Batt. Mode)
Pure Sinewave
EFFICIENCY
AC Mode
89%
Battery Mode
87%
BATTERY
Battery Type
12 V / 9 Ah
Numbers
4
Typical Recharge Time
4 hours recover to 90% capacity
Charging Voltage
54.7 VDC ±1%
INDICATORS
LCD Panel
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continuously sounding
PHYSICAL
Dimension, D x W x H (mm)
410 x 483 x 88 [2U]
Net Weight (kgs)
19
ENVIRONMENT
Humidity
20-90 % RH @ 0- 40°C (non-condensing)
Noise Level
Less than 50dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB
Supports Windows ?
2000/2003/XP/Vista/ 2008, Windows? 7/8, Linux, Unix, and MAC
Optional SNMP (SNMP NETWORK CARD need to be purchased separately)
Power management from SNMP manager and web browser
NOTE 1: Derate to 80% of capacity in CVCF mode or when the output voltage is adjusted to 200/208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
What’s in the box
1x UPS Unit
1x Power Cable
1x VGA Cable
1x MALE TO FEMALE EXTENSION POWER CORD IEC C13-C14 (From UPS to PC)
1x USB Cable (From UPS to PC)
1x Driver Disk
1x User Guide
1x RACK MOUNT KIT FOR MECER UPS (UPS-RACKMOUNT)
1x Stand