Mecer Winner Pro 2000Va 2U On-Line Rackmount Ups (Uninterruptable Power Supply)


MECER
MECER WINNER PRO 2000VA 2U ON-LINE RACKMOUNT UPS
Mecer 2000VA / 1600W 2U ON-LINE SINE WAVE Rackmountable UPS (with Monitoring Software) -Black
Product Code ME-2000-WPRU
EAN Code ME-2000-WPRU
Features

True double-conversion online UPS
Wide input voltage range (110-300 VAC)
Input power factor correction 0.99
Output power factor 0.8
Converter mode available
ECO mode operation for energy saving (only available for 1-3KVA)
Hot-swappable battery design only available for 1-3KVA
Generator compatible
Adjustable charging current via LCD or software (1A ~ 6A)

Specifications
Colour
Black

PHASE
Single phase with ground

CAPACITY
2000 VA / 1600 W

INPUT

Voltage Range

Low Line Transfer
160 VAC/140 VAC/120 VAC/110 VAC ± 5% (Ambient Temp. (based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)

Low Line Comeback
175 VAC /155 VAC/ 135 VAC /125 VAC± 5 % (Ambient Temp. (based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)

High Line Transfer
300 VAC ± 5 %

High Line Comeback
290 VAC ± 5 %

Frequency Range
40Hz ~ 70 Hz

Power Factor
? 0.99 @ nominal voltage

OUTPUT

Output Voltage
200/208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode)
± 1%

Frequency Range (Synchronized Range)
47 ~ 53 Hz or 57 ~ 63 Hz

Frequency Range (Batt. Mode)
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz

Current Crest Ratio
3:1

Harmonic Distortion
? 3 % THD (Linear Load),
? 6% THD (non-linear load)

Transfer Time

AC Mode to Batt. Mode
Zero

Inverter to Bypass
4 ms (Typical)

Waveform (Batt. Mode)
Pure Sinewave

EFFICIENCY

AC Mode
89%
Battery Mode
87%

BATTERY

Battery Type
12 V / 9 Ah

Numbers
4

Typical Recharge Time
4 hours recover to 90% capacity

Charging Voltage
54.7 VDC ±1%
INDICATORS

LCD Panel
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

ALARM

Battery Mode
Sounding every 4 seconds

Low Battery
Sounding every second

Overload
Sounding twice every second

Fault
Continuously sounding

PHYSICAL

Dimension, D x W x H (mm)
410 x 483 x 88 [2U]
Net Weight (kgs)
19
ENVIRONMENT

Humidity

20-90 % RH @ 0- 40°C (non-condensing)

Noise Level
Less than 50dB @ 1 Meter

MANAGEMENT

Smart RS-232/USB
Supports Windows ?
2000/2003/XP/Vista/ 2008, Windows? 7/8, Linux, Unix, and MAC

Optional SNMP (SNMP NETWORK CARD need to be purchased separately)
Power management from SNMP manager and web browser

NOTE 1: Derate to 80% of capacity in CVCF mode or when the output voltage is adjusted to 200/208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.

What’s in the box
1x UPS Unit
1x Power Cable
1x VGA Cable
1x MALE TO FEMALE EXTENSION POWER CORD IEC C13-C14 (From UPS to PC)
1x USB Cable (From UPS to PC)
1x Driver Disk
1x User Guide
1x RACK MOUNT KIT FOR MECER UPS (UPS-RACKMOUNT)
1x Stand

R8,576.40

MECER
MECER WINNER PRO 2000VA 2U ON-LINE RACKMOUNT UPS
Mecer 2000VA / 1600W 2U ON-LINE SINE WAVE Rackmountable UPS (with Monitoring Software) -Black
Product Code ME-2000-WPRU
EAN Code ME-2000-WPRU
Features

True double-conversion online UPS
Wide input voltage range (110-300 VAC)
Input power factor correction 0.99
Output power factor 0.8
Converter mode available
ECO mode operation for energy saving (only available for 1-3KVA)
Hot-swappable battery design only available for 1-3KVA
Generator compatible
Adjustable charging current via LCD or software (1A ~ 6A)

Specifications
Colour
Black

PHASE
Single phase with ground

CAPACITY
2000 VA / 1600 W

INPUT

Voltage Range

Low Line Transfer
160 VAC/140 VAC/120 VAC/110 VAC ± 5% (Ambient Temp. (based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)

Low Line Comeback
175 VAC /155 VAC/ 135 VAC /125 VAC± 5 % (Ambient Temp. (based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)

High Line Transfer
300 VAC ± 5 %

High Line Comeback
290 VAC ± 5 %

Frequency Range
40Hz ~ 70 Hz

Power Factor
? 0.99 @ nominal voltage

OUTPUT

Output Voltage
200/208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode)
± 1%

Frequency Range (Synchronized Range)
47 ~ 53 Hz or 57 ~ 63 Hz

Frequency Range (Batt. Mode)
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz

Current Crest Ratio
3:1

Harmonic Distortion
? 3 % THD (Linear Load),
? 6% THD (non-linear load)

Transfer Time

AC Mode to Batt. Mode
Zero

Inverter to Bypass
4 ms (Typical)

Waveform (Batt. Mode)
Pure Sinewave

EFFICIENCY

AC Mode
89%
Battery Mode
87%

BATTERY

Battery Type
12 V / 9 Ah

Numbers
4

Typical Recharge Time
4 hours recover to 90% capacity

Charging Voltage
54.7 VDC ±1%
INDICATORS

LCD Panel
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

ALARM

Battery Mode
Sounding every 4 seconds

Low Battery
Sounding every second

Overload
Sounding twice every second

Fault
Continuously sounding

PHYSICAL

Dimension, D x W x H (mm)
410 x 483 x 88 [2U]
Net Weight (kgs)
19
ENVIRONMENT

Humidity

20-90 % RH @ 0- 40°C (non-condensing)

Noise Level
Less than 50dB @ 1 Meter

MANAGEMENT

Smart RS-232/USB
Supports Windows ?
2000/2003/XP/Vista/ 2008, Windows? 7/8, Linux, Unix, and MAC

Optional SNMP (SNMP NETWORK CARD need to be purchased separately)
Power management from SNMP manager and web browser

NOTE 1: Derate to 80% of capacity in CVCF mode or when the output voltage is adjusted to 200/208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.

What’s in the box
1x UPS Unit
1x Power Cable
1x VGA Cable
1x MALE TO FEMALE EXTENSION POWER CORD IEC C13-C14 (From UPS to PC)
1x USB Cable (From UPS to PC)
1x Driver Disk
1x User Guide
1x RACK MOUNT KIT FOR MECER UPS (UPS-RACKMOUNT)
1x Stand

SKU: MUS-ME-2000-WPRU Category: